| SL# | Item Code | Item Description | Unit |
Rate for ZoneA Dhaka & Mymensingh Division |
Rate for ZoneB Chattogram & Sylhet Division |
Rate for ZoneC Rajshahi & Rangpur Division |
Rate for ZoneD Khulna & Barishal Division |
|---|---|---|---|---|---|---|---|
| DIVISION 28 : GAS CONNECTION WORKS | |||||||
| 2031. | 28.1 | Pipe line installation: Installation of 50 psi, APl, 5L, Grade-B, ERW Natural pipe line for supplying Titas Gas including, supplying, fitting, fixing and laying different sizes M.S. pipes with necessary tape and primer including cutting trenches (450 mm x 910 mm) in all kinds of soil, cleaning, cutting, applying coal-tar, wrapping the pipes, marking the pipeline with 200mm X 200mm demarcation plate (C.C./ M.S. plate) @ 15m interval and back filling the trenches, excavating earth including. leveling, dressing and removing excess earth in all respect as per specification of Titas Gas T and D Co. Ltd. and accepted by the Engineer-in-charge. [Rate is excluding the cost of welding and back filling with sand at the bottom by 300 mm in thickness (compacted)] (Pipes manufactured by National Tubes Limited under Steel & Engineeing Corporation, Ministry of Industries, Government of Bangladesh shall be given priority) | |||||
| 2032. | 28.1.1 | 100 mm ND (114.30 mm O.D) M.S pipe, weight of min 14.4 kg/m, standard test pressure 176 kg/ m2, wall thickness of min 5.4 mm | meter | 4179 | 4003 | 3983 | 3983 |
| 2033. | 28.1.2 | 75 mm N.D (88.90 mm O.D) M.S pipe, weight of min 10.1 kg/m, standard test pressure 176 kg/ m2, wall thickness of min 4.85 mm | meter | 2386 | 2283 | 2266 | 2266 |
| 2034. | 28.1.3 | 50 mm N.D. (60.30 mm O.D) M.S pipe, weight of min 6.17 kg/m, standard test pressure 176 kg/ m2, wall thickness of min 4.47 mm | meter | 1447 | 1383 | 1365 | 1365 |
| 2035. | 28.1.4 | 25 mm N.D. (33.80 mm O.D) M.S pipe weight of min 3.84 kg/m, standard test pressure 50 kg/ m2, wall thickness of min 4.05 mm | meter | 870 | 829 | 811 | 811 |
| 2036. | 28.1.5 | 20 mm N.D. (27.20 mm O.D) M.S pipe weight of min 1.90 kg/m, standard test pressure 50 kg/ m2, wall thickness of min 3.25 mm | meter | 683 | 649 | 632 | 632 |
| 2037. | 28.10 | Cutting of permanent pucca (rigid/flexible) road and mending good the damages etc. all complete in all respect and accepted by the Engineer-in-charge. | |||||
| 2038. | 28.10.1 | Bituminous Road | sqm | 1356 | 1277 | 1182 | 1182 |
| 2039. | 28.10.2 | R.C.C. Road | sqm | 2027 | 1910 | 1769 | 1769 |
| 2040. | 28.11 | Testing and purging of the house line properly as per specifications Titas Gas T and D Co. Ltd. and accepted by the Engineer-in-charge. | meter | 29 | 28 | 28 | 28 |