List of Long Schedules
SL# Item Code Item Description Unit Rate for ZoneA
Dhaka & Mymensingh Division
Rate for ZoneB
Chattogram & Sylhet Division
Rate for ZoneC
Rajshahi & Rangpur Division
Rate for ZoneD
Khulna & Barishal Division
DIVISION 09: PILE WORKS AND PILE TEST
491. 09.24.2 For PIT test of each additional pile after 12(Twelve) pile tested at same site per pile 1472 1472 1472 1472
492. 09.25 Pre-cast spliced pile jointing by supplying, fitting, fixing prefabricated square shaped two steel caps made up by 6 mm thick ASTM A36 complied M.S plate, sides formed by bent in channel shape to have only two line of joinery on faces, having min 50 mm dia hole on its web; capping by min 12 mm thick ASTM A36 complied M.S plate shaping the edges in 45°, having min 40 mm dia hole at centre to pass 25 mm M.S bar 433 mm in length; jointed at channels root by welding; caps fitted with 2 nos BDS ISO 6935-2009: B400 DWR complied d20 U-bar 1244mm in length by welding, equidistant from centre holes of cap and shall have min 75 mm clear from pile faces; and finally, the system to be fitted in correct alignments on pile head positions waiting for concreting; both the pile heads fitted with the steel caps to be welded together through v-notches in field, while one of the companion segment of piles drived in ground and other one placed over it maintaining true verticality; all complete as per direction and stepwise approval leading to final approval of Engineer-in- charge.
493. 09.25.1 X-sec of pre cast pile segments :300 mm x 300 mm each 10599 12285 12219 12219
494. 09.25.2 X-sec of pre cast pile segments :350 mm x 350 mm each 12021 14289 14223 14223
495. 09.25.3 X-sec of pre cast pile segments :400 mm x 400 mm each 13595 16523 16457 16457
496. 09.25.4 X-sec of pre cast pile segments :450 mm x 450 mm each 13951 15582 15520 15520
497. 09.26 Pile Driving by Hydraulic Static Pile Driver
498. 09.26.1 Mobilization and demobilzation of hydraulic static pile driver(Upto 320 metric ton capacity) per set per site 559524 559524 559524 559524
499. 09.26.2 Mobilization and demobilzation of hydraulic static pile driver(321 Metric Ton to 500 Metric Ton Capacity) per set per site 671429 671429 671429 671429
500. 09.26.2.1 Driving pre-cast pile of 300 mm x 300 mm to 350 mm x 350 mm X-section made with shoe/ without shoe by Hydraulic static pile driver of upto 320 tonne (metric ton) capacity; arranged with necessary cranes, power source, maintaining driving log and record of pressure exerted on piles driven in to desired RL or capacity level ; complete in all respect including handling of piles, dressing & leveling of site, way making, surveying, layout setting etc ended with the submission of pile driving report in three copies duly signed by professional engineer and approved by the Engineer-in-charge. meter 886 885 883 883
Help