| SL# | Item Code | Item Description | Unit |
Rate for ZoneA Dhaka & Mymensingh Division |
Rate for ZoneB Chattogram & Sylhet Division |
Rate for ZoneC Rajshahi & Rangpur Division |
Rate for ZoneD Khulna & Barishal Division |
|---|---|---|---|---|---|---|---|
| DIVISION 20 : STAIR & VERANDAH RAILING AND STAIR NOSING | |||||||
| 1111. | 20.14.4 | Supplying, fitting and fixing verandah railing of standard height with 2 mm thick 62 mm dia SS pipe for hand-rail, 2 mm thick 50mm dia vertical SS post having pipe holder to provide hand rail and SS knob for horizontal pipe @ 900mm c/c fitting by welding on 150 mm x 150 mm x 6 mm SS anchor plate at base, base plate fitting with the floor by 50mm long royal bolt, 1.5 mm thick 25 mm dia 8 nos horizontal SS pipes fitting with SS knob of vertical post including carrying, polishing fabricating etc. all complete and accepted by the Engineer-in-charge. | sqm | 11946 | 11932 | 11856 | 11856 |
| 1112. | 20.15.1 | Supplying, fitting and fixing 10 mm thick tempered glass railing in verandah with 62mm dia 2 mm thick SS pipe for hand rail, 62 mm x 50 mm x 2 mm SS vertical box fitted with concrete slab by 100 mm x 55 mm x 6 mm SS plate @ 600 mm c/c and base plate fitting with the floor by 50mm long royal bolt including all fittings, fixtures as per drawing, desing and specification etc all complete in all respect and accepted by Engineer-in-charge. | sqm | 11949 | 11937 | 11867 | 11867 |
| 1113. | 20.15.2 | Supplying, fitting and fixing 10 mm thick tempered glass railing in verandah of standard height with 2 mm thick 62 mm dia SS pipe for hand-rail, 2 mm thick 50 mm dia SS vertical post having pipe holder to provide hand rail and SS glass holder @ 900mm c/c fitting by welding on 100 mm x 100 mm x 6 mm SS anchor plate at base, base plate fitting with the floor by 50mm long royal bolt, 10 mm thick Tempered glass fitting between the post through glass holder as per drawing, design including carrying, polishing fabricating etc. all complete and accepted by the Engineer-in-charge. | sqm | 11779 | 11768 | 11700 | 11700 |
| 1114. | 20.15.3 | Supplying, fitting and fixing 10 mm thick tempered glass railing in verandah of standard height with 1.5 mm thick 50mm x 15mm SS U channel at top of rail, fitting the tempered glass with 150mm/200 mm long SS glass clamp @ 900mm c/c, welding the SS glass clamp on 100 mm x 100 mm x 6 mm SS base plate and fitting base plate with the floor by 50mm long royal bolt including welding, bending, fabricating, polishing all complete as per drawing, desing and specification etc in all respect and accepted by Engineer-in-charge. | sqm | 10735 | 10725 | 10663 | 10663 |
| 1115. | 20.16 | Supplying, fitting and fixing 10 mm thick tempered glass railing in verandah of standard height with 3mm thick 50mm x 50mm square MS box for hand rail, 3mm thick 75mm x 38mm mm MS vertical post box @ 900 mm c/c fitting by welding on 150 mm x 100 mm x 6 mm anchor plate at base, base plate fitting with the floor by 50mm long royal bolt, fitting 10mm thick tempered glass between the vertical post through glass holder, applying 2 (two) coats of synthetic enamel paint of approved quality over an anti-corrosive prime coat including all other accessories and carrying, fabricating etc. all complete and accepted by the Engineer-in-charge. (Rate is excluding the cost of painting). | sqm | 9092 | 9078 | 8997 | 8997 |
| 1116. | 20.17.1 | Supplying, fitting and fixing verandah railing of standard height with 3mm thick 75mm x 50mm MS box for vertical post box @ 900 mm c/c fitting by welding on 150 mm x 100 mm x 6 mm anchor plate at base, base plate fitting with the floor by 50mm long royal bolt, 3mm thick 50mm x 38mm MS horizontal box fitting with the vertical post by welding @ 150 mm c/c including all other accessories and carrying, febrication, applying 2 (two) coats of synthetic enamel paint of approved quality over an anti-corrosive prime coat etc. complete in all respect for all floors and accepted by the Engineer-in-charge. (Exposed area of railing will be considered for measurement, rate is excluding the cost of painting). | sqm | 5858 | 5841 | 5753 | 5753 |
| 1117. | 20.17.2 | Supplying, fitting and fixing verandah railing of standard height with 5mm thick 75mm x 75mm MS box for vertical post box @ 900 mm c/c fitting by welding on 150 mm x 150 mm x 6 mm anchor plate at base, base plate fitting with the floor by 50mm long royal bolt, fitting 5mm thick 50mm x 50mm MS horizontal box with the vertical post by welding at top of rail and 125mm above from the floor, 3mm thick 25mm x 25mm MS square box fitting by welding vertically @ 150 mm c/c between the top and bottom rail including all other accessories and carrying, febrication, applying 2 (two) coats of synthetic enamel paint of approved quality over an anti-corrosive prime coat etc. complete in all respect for all floors and accepted by the Engineer-in-charge. (Exposed area of railing will be considered for measurement, rate is excluding the cost of painting). | sqm | 6531 | 6515 | 6426 | 6426 |
| 1118. | 20.17.3 | Supplying, fitting and fixing verandah railing of standard height with 5mm thick 75mm x 50mm MS box for vertical post box @ 900 mm c/c fitting by welding on 150 mm x 150 mm x 6 mm anchor plate at base, base plate fitting with the floor by 50mm long royal bolt, 5mm thick 75mm x 50mm MS horizontal box fitting by welding with the vertical post for hand rail, 2 nos. 5mm thick 50mm x 50mm MS horizontal box fitting with the vertical post by welding 125 mm below the top rail and 125 mm above the floor, 3mm thick 25mm x 25mm MS square box fitting by welding vertically @ 150 mm c/c between the 2 nos. 50mm x 50mm horizontal MS box including all other accessories and carrying, febrication, applying 2 (two) coats of synthetic enamel paint of approved quality over an anti-corrosive prime coat etc. complete in all respect for all floors and accepted by the Engineer-in-charge. (Exposed area of railing will be considered for measurement, rate is excluding the cost of painting). | sqm | 6958 | 6941 | 6853 | 6853 |
| 1119. | 20.18.1 | Providing 38 mm x 38 mm x 6 mm M.S. angle to the nosing of steps of staircase | meter | 479 | 500 | 493 | 493 |
| 1120. | 20.18.2 | Providing nosing 32 mm x 32 mm x 6 mm M.S. angle to the nosing of steps of stair case. | meter | 421 | 438 | 431 | 431 |