DIVISION 26 : SANITARY & WATER SUPPLY WORKS
1511. Supplying, fitting and fixing of best quality sink cock made from copper or copper alloy, chromium plated. The faucet conforms BDS EN 200:2009 . The faucet tap shall be free from any leakage, permeation and other abnormalities. The water hammer value shall be 1.47 Mpa or under. The faucet after it has been operated 100000 times it shall be free from a seat- leakage and shall satisfy the reverse flow preventing performance. The inside and outside surfaces of the faucet shall be smooth and be free from blowholes, fissures, remarkable flows or injurious defects. The chromium plating on the faucet shall be of class 2 grade 1. The final coating should be done with chromium of minimum 0.1 micron. The faucet shall be made leak proof and fixing in position with selected tape etc. , all complete approved and accepted by the Engineer- in- charge.
1512. Supplying, fitting and fixing of best quality CP basin/sink mixer The faucet conforms BDS EN 200:2009. The faucet tap shall be free from any leakage, permeation and other abnormalities. The water hammer value shall be 1.47 Mpa or under. The faucet after it has been operated 100000 times it shall be free from a seat- leakage and shall satisfy the reverse flow preventing performance. The inside and outside surfaces of the faucet shall be smooth and be free from blowholes, fissures, remarkable flows or injurious defects. The chromium plating on the faucet shall be of class 2 grade 1. The final coating should be done with chromium of minimum 0.1 micron. The faucet shall be made leak proof and fixing in position with selected tape etc. , all complete approved and accepted by the Engineer- in- charge.
1513. Supplying, fitting and fixing of best quality 20 mm CP shower mixer. The faucet conforms BDS EN 200:2009. The faucet tap shall be free from any leakage, permeation and other abnormalities. The water hammer value shall be 1.47 Mpa or under. The faucet after it has been operated 100000 times it shall be free from a seat- leakage and shall satisfy the reverse flow preventing performance. The inside and outside surfaces of the faucet shall be smooth and be free from blowholes, fissures, remarkable flows or injurious defects. The chromium plating on the faucet shall be of class 2 grade 1. The final coating should be done with chromium of minimum 0.1 micron. The faucet shall be made leak proof and fixing in position with selected tape etc. , all complete approved and accepted by the Engineer- in- charge.
1514. Supplying, fitting and fixing of best quality Bathtub mixer. The faucet conforms BDS EN 200:2009. The faucet tap shall be free from any leakage, permeation and other abnormalities. The water hammer value shall be 1.47 Mpa or under. The faucet after it has been operated 100000 times it shall be free from a seat- leakage and shall satisfy the reverse flow preventing performance. The inside and outside surfaces of the faucet shall be smooth and be free from blowholes, fissures, remarkable flows or injurious defects. The chromium plating on the faucet shall be of class 2 grade 1. The final coating should be done with chromium of minimum 0.1 micron. The faucet shall be made leak proof and fixing in position with selected tape etc. , all complete approved and accepted by the Engineer- in- charge.
1515. PIPE AND PIPE FITTING ACCESSORIES
1516. PIPE ITEMS
1517. Supplying, fitting and fixing of 100 mm inside diameter & wall thickness 2.7 mm - 3.4 mm best quality uPVC rain water down pipe fitting, fixed in position with head and shoes, bends, min.20 mm width F.I. Bar clamp and nails, and including all accessories such as round grating/domed roof grating, bands, sockets approved and accepted by the Engineer- in- charge. meter 993 988 970 970
1518. Supplying, laying, fitting and fixing of best quality HDPE soil, waste and ventilation pipe having PE-100 (Hydrostatic Strength for PE-100 is 5.0 MPa & 12.4 Mpa at 80°c & 20°c respectively according to ISO 4427:2007(E)), PN-6 (nominal pressure for PN-6 is 0.6 MPa according to ISO 4427:2007(E) ) & SDR 26 for soil, waste and ventilation pressure pipe having density 0.940 – 0.970 gm/cm3 and other physical, chemical, thermal, fire resistivity properties etc. as per BSTI approved manufacturer standards or ASTM/BS/ISO/IS standards ,fitted and fixed in position with necessary joints and fittings with all accesories complete approved and accepted by the Engineer- in- charge.
1519. Supplying, fitting and fixing of best quality Single lever angle stop mixer. The faucet conforms BDS EN 200:2009. The faucet tap shall be free from any leakage, permeation and other abnormalities. The water hammer value shall be 1.47 Mpa or under. The faucet after it has been operated 100000 times it shall be free from a seat- leakage and shall satisfy the reverse flow preventing performance. The inside and outside surfaces of the faucet shall be smooth and be free from blowholes, fissures, remarkable flows or injurious defects. The chromium plating on the faucet shall be of class 2 grade 1. The final coating should be done with chromium of minimum 0.1 micron. The faucet shall be made leak proof and fixing in position with selected tape etc. , all complete approved and accepted by the Engineer- in- charge. each 2283 2281 2273 2273
1520. Supplying and fitting-fixing Chromium plated (CP) Shower head. all complete approved and accepted by the Engineer- in- charge.