| SL# | Item Code | Item Description | Unit |
Rate for ZoneA Dhaka & Mymensingh Division |
Rate for ZoneB Chattogram & Sylhet Division |
Rate for ZoneC Rajshahi & Rangpur Division |
Rate for ZoneD Khulna & Barishal Division |
|---|---|---|---|---|---|---|---|
| DIVISION 07 : REINFORCED CEMENT CONCRETE (RCC) WORKS | |||||||
| 331. | 07.1.4 | Cornice, railing, drop wall, louver, fins, sunshade, false ceiling, waffle and ribbed floor slab etc. up to ground floor | cum | 9399 | 9387 | 9200 | 9128 |
| 332. | 07.10 | Added rate for RCC works/fair-faced concrete works (materials, consumables and laying/placing concrete) in column, column capital, lift wall & wall, T- beam, L-beam, rectangular beams, floor / roof slab, cantilever slab, waffle slab and drop panels where the free height of the structure exceeds 4 meter (rate is considered for each additional meter height) | cum | 400 | 394 | 366 | 366 |
| 333. | 07.11.1 | Added rate for RCC work/fair-faced work in additional floor: concrete | cum | 93 | 93 | 93 | 93 |
| 334. | 07.11.2 | Added rate for RCC work in additional floor: concrete (concrete from batching or Ready-Mix Plant) | |||||
| 335. | 07.11.2.1 | Add for each cum of concrete from 5th floor to 14th floor: | cum | 19 | 19 | 19 | 19 |
| 336. | 07.11.2.2 | Add for each cum of concrete above 15th floor: | cum | 47 | 47 | 47 | 47 |
| 337. | 07.12 | Centering and shuttering, including strutting, propping etc. (The formwork must be rigid enough both in and out of plane, to make the concrete surface true to the designed shape and size by using necessary MS sheets of minimum 16 BWG, angles of minimum size 40 mm x 40 mm x 5 mm, flat bars etc.) and removal of form for: | |||||
| 338. | 07.12.1 | Individual and combined footing | sqm | 582 | 583 | 572 | 572 |
| 339. | 07.12.10 | Stair case slab and steps up to ground floor | sqm | 551 | 555 | 551 | 551 |
| 340. | 07.12.11 | Waffle or ribbed floor upto ground floor | sqm | 720 | 723 | 717 | 717 |