DIVISION 10 : STRUCTURAL STEEL WORKS, SHEET ROOFING AND SAFETY CANOPY
591. 10.25 Supply and installation of double bubble foil insulation at wall and roof of nominal thickness of 8 mm conforming to Class A in accordance with the ASTM-E84-09 fire test standard, including the cost of lapping, costape, adhesive and necessary accessories, all complete as per drawing, specification and direction of Engineer-in-charge. sqm 251 251 251 251
592. 10.26 Premium Synthetic Enamel paint of approved best quality and colour delivered from authorized local agent of the manufacturer(Berger robbialac supergloss synthetic enamel/Elite lucky seven/ Asian apcolipe premium paint or equivalent brand) in a sealed container, having highly water resistant, high bondibilty, flexiblity property; using specified brand thinner applying to metallic surface by spray in two coats over single coat anti-corrosive coating including cleaning drying, making free from dirt, grease, wax, removing all chalked and scaled materials, all complete in all floors accepted by the Engineer-in-charge. (payment shall be made on strucutral steel weight basis) kg 9 9 9 9
593. 10.27 Supply and application of Epoxy based corrosion protection paint to the surface of the structural steel members conforming to SA 2.5; the corrosion class shall be -C3 in accordance with BS EN ISO 12944-2 and durability class in accordance with BS EN ISO 12944-5; the Steel members to be shot blasted inside the enclosed shot blasting chamber, final coat paint must be applied on site after installation, including the cost of primer, testing and necessaey accessories, all complete as per drawing, specification and direction of Engineer-in-charge. kg 26 36 36 36
594. 10.28 Supply and pouring of non-shrink grout to steel column bases conforming to ASTM C 109 having compressive strength not less than 45 MPa, including the cost of shutter and necessary accessories, all complete as per drawing, specification and direction of Engineer-in-charge. cum 147568 166709 166709 166709
595. 10.29 Saftey Canopy: Supplying temporary safety canopy around construction work place where public safety is likely to be endangered due to construction activities; which shall be made of truss system of steel sections (main frame) at 1800 mm c/c with purlins @ 750 mm c/c, making flooring system by corrugated galvanized iron sheets of thickness 0.45 mm, laying wire mesh net on iron sheets, providing continuous gutter along the edges of the building with downpipe @ 6000 mm c/c, including fitting and fixing in position providing necessary anchors, cables, wires, ties etc. by standard anchoring and welding, nut-bolts etc, all complete and accepted by the Engineer-in-charge sqm 2421 2455 2437 2437
596. 10.3 Supply, fabrication and installation of built-up sections i.e. columns, beams, rafters, bracings, struts etc (up to level-4) from steel plates conforming to ASTM A36, with a minimum yield strength of 250 MPa, including the cost of testing of plates, application of red/grey-oxide primer etc. all complete as per drawing, specification and direction of Engineer-in-charge. kg 134 179 179 179
597. 10.30 Safety net with G.I Wire: Supply, fabrication, installation and taking out temporary horizontal safety net around construction work place where public safety is likely to be endangered due to construction activities; which shall be made of Chain link net with 24 BWG wire fitted at 15'-0'' height horizontally of the outer periphery of the building with 75mmx40mmx5mm MS Chanel post and purlin,20mm MS Rod and 40mmx40mmx6mm MS Angle as ties etc. by standard anchoring and welding, nut-bolts etc, all complete and accepted by the Engineer-in-charge( Salvage materials shall be the contractors property after completion of work.) sqm 1515 1529 1510 1510
598. 10.31 Safety shed over drive way : Supply, fabrication, installation and taking out temporary horizontal safety shed over the drive way around construction work place where public safety is likely to be endangered due to construction activities; which shall be made of 0.27 mm thick galvanized iron plain sheet fitted at 15'-0'' height horizontally over the drive way or path way at the outer periphery of the building with 75mm x 40mm x 5 mm M.S Chanel post and purlin,20mm MS Rod and 40mmx40mmx6mm MS Angle as ties etc. by standard anchoring and welding, nut-bolts etc, all complete and accepted by the Engineer-in-charge( Salvage materials shall be the contractors property after completion of work.) sqm 1638 1659 1631 1631
599. 10.32 Scaffolding for outside netting of building: Supplying, fitting & fixing scaffolding for outside netting of building with single layer 38 mm dia MS pipe connected each other with minimum 4'-0" centre to centre both direction with 38 mm dia swivel clamp,including fitting and fixing in position providing necessary anchors, wires, ties etc. all complete and accepted by the Engineer-in-charge. (Rate is excluding the cost of netting) sqm 348 348 348 348
600. 10.33 Saftey net: Supplying temporary safety net (hessian cloth) around construction work place (along the height of the building) where public safety is likely to be endangered due to construction activities; which shall be supported using scaffolding around the building for brick work/ plaster; including fitting and fixing in position providing necessary anchors, wires, ties etc. all complete and accepted by the Engineer-in-charge. (Rate is excluding the cost of scaffolding) sqm 51 51 50 50