| DIVISION 18 : FALSE CEILING, WALL PANELING & ACOUSTIC ITEMS | |||||||
| 1061. | 18.7.3.1 | Supplying, fitting and fixing of 15 mm thick Fire Retardent, heat Insulated, Acoustic Mineral fiber board (any colour) ceiling (drop/ plain/ straight/ curve) (Made in Thailand/ China/ India/ Malayasia or equivalent quality product) with high grade mineral wool, surface finish with white ultra vinyl latex paint, surface treatment-film coating, anti-fungal & anti bacterial, humidity resistant greater than 90%, light reflectivity more than 90%, NRC value 0.60- 0.90, density-290-315 kg/m3, size of board: 600mm x 600mm, of imcombustible materials, framing by aluminium T-bar of natural anodized finish suspended in 600 mm x 600 mm grid from ceiling using butterfly hanger with adjustable clip/ locking clips etc. including cost of all materials, electricity, accessories, scaffoldings, labour for installation, screws, nails, rivet etc. all complete as per drawing, architectural and acoustic design (NRC 0.6-0.9) and accepted by the Engineer-in-charge. Measurement will be taken as per finished surface area. The brick/ RCC surface shall be dry and damp-proof. (This item is for acoustic work in auditorium, Hall Room, Seminar Room etc.) (Rate is excluding cost of polish/ paint etc. of any type). | sqm | 2166 | 2154 | 2126 | 2126 |
| 1062. | 18.7.3.2 | Supplying, fitting and fixing of 15 mm thick Fire retardent, heat Insulated, Acoustic Mineral fiber board ceiling, (drop/ plain/ straight/ curve) (Made in UK/Germany/ Italy/ France or equivalent quality product) with high grade mineral wool, surface finish with white ultra vinyl latex paint, surface treatment-film coating, anti-fungal & anti bacterial humidity resistant greater than 90%, light reflectivity more than 90%, NRC value 0.60- 0.90, density-290-315 kg/m3, size of board: 600mm x 600mm, of imcombustible materials, framing by aluminium T-bar of natural anodized finish suspended in 600 mm x 600 mm grid from ceiling using butterfly hanger with adjustable clip/ locking clips etc. including cost of all materials, electricity, accessories, scaffoldings, labour for installation, screws, nails, rivet etc. all complete as per drawing, architectural and acoustic design (NRC 0.6-0.9) and accepted by the Engineer-in-charge. Measurement will be taken as per finished surface area. The brick/ RCC surface shall be dry and damp-proof. (This item is for acoustic work in auditorium, Hall Room, Seminar Room etc.) (Rate is excluding cost of polish/ paint etc. of any type). | sqm | 4385 | 4373 | 4345 | 4345 |
| 1063. | 18.7.3.3 | Supplying, fitting and fixing of 20mm thick Mineral Fiber Acoustic ceiling, (drop/ plain/ straight/ curve) (Made in UK/Germany/ Italy/ France or equivalent quality product) with high grade mineral wool, surface finish with white ultra vinyl latex paint, surface treatment-film coating, anti-fungal & anti bacterial humidity resistant greater than 90%, light reflectivity more than 90%, NRC value 0.90 -1.00, medium density, size of board: 600mm x 600mm, fire rating B1 standard, framing with 600mm x 600 mm grid suspended from ceiling using screw, nut, adjustable hanger hook, anchor, T-Grid, Wall angle, Main runner, thread rod, 38mm carrier bracket, connector, sleeve anchor, suspension bracket etc. all complete as per drawing, architectural and acoustic design (NRC 0.9-1.0) and accepted by the Engineer-in-charge. Measurement will be taken as per finished surface area. The brick/ RCC surface shall be dry and damp-proof.(This item is for acoustic work in auditorium, Hall Room, Seminar Room etc.) (Rate is excluding cost of polish/ paint etc. of any type). | sqm | 9929 | 9907 | 9873 | 9873 |
| 1064. | 18.7.3.4 | Supplying, fitting and fixing of 20mm thick Mineral Fiber Acoustic ceiling, (drop/ plain/ straight/ curve) (Made in China/Malaysia/Thailand/India or equivalent quality product) with high grade mineral wool, surface finish with white ultra vinyl latex paint, surface treatment-film coating, anti-fungal & anti bacterial humidity resistant greater than 90%, light reflectivity more than 90%, NRC value 0.90 -1.00, medium density, size of board: 600mm x 600mm, fire rating B1 standard, framing with 600mm x 600 mm grid suspended from ceiling using T-Grid, Wall angle, Main runner, 38mm carrier bracket, adjustable hanger hook, thread rod, anchor, screw, nut, connector, sleeve anchor, suspension bracket etc. all complete as per drawing architectural and acoustic design (NRC 0.9-1.0) and accepted by the Engineer-in-charge. Measurement will be taken as per finished surface area. The brick/ RCC surface shall be dry and damp-proof.(This item is for acoustic work in auditorium, Hall Room, Seminar Room etc.) (Rate is excluding cost of polish/ paint etc. of any type). | sqm | 6342 | 6319 | 6286 | 6286 |
| 1065. | 18.7.4 | Supplying, fitting and fixing of Ply board C-section or box type work on wall/Ceiling. Using C-section of 150mm x 200mm x 150mm or any size of thickness 18mm with facing 50mm, in/c substruction of garjan wooden framing (50mm x 38mm @600mm c/c) and screwed, for additional load suppport in/c special made full thread 8mm dia rod fixed to the ceiling or roof or beam by rowel bolt, all complete as per drawing, design and accepted by the Engineer-in-charge. All Garjan wood frames must be protected from termites, cockroach and other insects. Measurement will be taken as per finished surface area. The brick/ RCC surface shall be dry and damp-proof. (This item is for acoustic work in auditorium, Hall Room, Seminar Room etc.) (Rate is excluding cost of polish/ paint etc. of any type). | sqm | 5480 | 5371 | 5491 | 5491 |
| 1066. | 18.8 | Additional Rate of scaffolding for walling or ceiling work (from Item no. 18.1 to 18.7) | |||||
| 1067. | 18.8.1 | From 4m up to 6 m | Sqm | 132 | 132 | 132 | 132 |
| 1068. | 18.8.2 | Beyond 6m to above height | Sqm | 264 | 264 | 264 | 264 |
| 1069. | 18.9 | Supplying, fitting, fixing CNC Cutted facade work made of 5 mm(+-3%) thick MS Plate, pre-treated & painted with industrial paint/ powder coated glossy paint (thickness not less than 70 micron) covered by water colour weather proof paint, supported by 50mm x 50 mm x 5mm MS angle at Top & Side of outer frame according to drawing & design, fitted and fixed in wall/ RCC members with necessary number of clamps, intermediate struts, royal bolt with epoxy. Segments of MS plate will be smoothly joined by rivets or welding, aligned and levelled. Cost is inclusive electricity, workshop charges, loading - unloading, lifting, carrying and placing to the required place & position etc. all complete as per approved design and drawing and accepted by the Engineer-in-charge.(Upto a height of 20m) | sqm | 7967 | 9974 | 9947 | 9947 |
| DIVISION 19 : COLLAPSIBLE GATE, M.S. GATE, ROLLING SHUTTER ETC. | |||||||
| 1070. | 19.1.1 | Manufacturing, supplying, fitting and fixing S.S. collapsible gate of any design and shape made of 25 mm x 25 mm x 3 mm S.S. angle placed @ 112 mm c/c vertically and connecting the same with each other by 25 mm x 3 mm S.S flat bar scissors 525 mm, 600 mm long provided in 3 rows including cutting the different S.S. members to required sizes, fabricating, welding, riveting with required size rivets, providing required size wheels, pulling handles on both sides, suitable locking arrangement, electrodes, grease and finally placing the same in position in between 2 (two) nos. 50 mm x 50 mm x 6 mm S.S. tee rail made by welding 2 nos. 50 mm x 6 mm S.S. flat bar fitted and fixed at top and bottom with R.C.C. lintel/ roof slab, floors and side wall with required nos. 150 mm to 225 mm long 38 mm x 6 mm S.S. flat bar clamps one end welded with the gate member and the other end bifurcated and embedded in C.C. at the respective point including cutting holes and mending good the damages by pouring concrete (1:2:4) into the holes and finishing, both end carriage, including polishing, greasing, electrodes, curing etc. complete as per drawing and design and accepted by the Engineer-in-charge . | |||||