| SL# | Item Code | Item Description | Unit |
Rate for ZoneA Dhaka & Mymensingh Division |
Rate for ZoneB Chattogram & Sylhet Division |
Rate for ZoneC Rajshahi & Rangpur Division |
Rate for ZoneD Khulna & Barishal Division |
|---|---|---|---|---|---|---|---|
| DIVISION 23 : FERROCEMENT WORKS | |||||||
| 1231. | 23.1.3 | Add for each additional floor above ground floor | sqm | 40 | 40 | 40 | 40 |
| 1232. | 23.2 | Supplying, fitting & fixing of 20 mm thick ferrocement folded plate roof which is made by using vibration table & steel shutter with minimum cement content relates to mix ratio 1:2, having minimum compressive strength of 30 MPa (28 days standard cube strength) and cement conforming to BDS EN-197-1-CEM-I, 52.5N (52.5MPa)/ASTM-C 150 type- 1, best quality coarse sand of equivalent F.M. 2.2, 1 layer of 20 BWG galvanized/epoxy coated wire mesh having minimum yield strength fy=450 MPa & having 2 meshes per 25 mm, fabrication and fixing to details as per design, deformed bar reinforcement BDS ISO 6935-2:2006, including straightening and cleaning the rust, if any, bending and binding in position with supply of 24 BWG GI wires, removing the shutter, lifting, keeping on proper position, curing at least for 7 days including the cost of water, electricity and other charges all complete as per design, drawing and accepted by the Engineer-in-charge. | |||||
| 1233. | 23.2.1 | For ground floor, span up to 3810 mm | sqm | 2271 | 2260 | 2214 | 2213 |
| 1234. | 23.2.2 | Add for each additional span length of 150 mm long direction (3810 mm < span ≤ 4800 mm) | sqm | 10 | 10 | 10 | 10 |
| 1235. | 23.2.3 | Add for each additional floor above ground floor | sqm | 40 | 40 | 40 | 40 |
| 1236. | 23.3 | Supplying, fitting & fixing of 20 mm thick ferrocement corrugated sheet roof which is made by using vibration table & steel shutter with minimum cement content relates to mix ratio 1:2, having minimum compressive strength of 30 MPa (28 days standard cube strength) and cement conforming to BDS EN-197-1-CEM-I, 52.5N (52.5MPa)/ASTM-C 150 type-1, best quality coarse sand of equivalent F.M. 2.2, 1 layer of 20 BWG galvanized/epoxy coated wire mesh having minimum yield strength fy=450 Mpa & having 2 meshes per 25 mm and supplying, fabrication and fixing to details as per design, deformed bar reinforcement BDS ISO 6935-2:2006 including straightening and cleaning rust, if any, bending and binding in position with supply of 24 nos GI wires, removing the shutter, lifting on ground floor roof, keeping on proper position, curing at least for 28 days including the cost of water, electricity and other charges all complete as per design, drawing and accepted by the Engineer-in-charge. | |||||
| 1237. | 23.3.1 | For ground floor, span up to 3810 mm for floor/roof slab. | sqm | 1849 | 1846 | 1817 | 1816 |
| 1238. | 23.3.2 | Add for each additional floor above ground floor | sqm | 40 | 40 | 40 | 40 |
| 1239. | 23.4 | Supplying, fitting & fixing of pre-cast Ferrocement L-Panel which is made by using vibration table & steel shutter with minimum cement content relates to mix ratio 1:2 for flange having minimum compressive strength of 30 MPa (28 days standard cube strength) and cement conforming to BDS EN-197-1-CEM-I, 52.5N (52.5MPa)/ASTM-C 150 type- 1, best quality coarse sand of equivalent F.M. 2.2, 2 layers of 20 BWG galvanized/epoxy coated wire mesh having minimum yield strength fy=450 Mpa & having 2 meshes per 25 mm and reinforced cement concrete works for rib with minimum cement content relates to mix ratio 1:1.5:3 having minimum f’cr = 30 MPa and satisfying a specified compressive strength f'c = 25 MPa, best quality coarse sand of equivalent F.M. 2.2 and 12 mm down well graded stone chips conforming to ASTM C-33, supplying, fabrication and fixing to details as per design, deformed bar reinforcement BDS ISO 6935-2:2006 including straightening and cleaning rust, if any, bending and binding in position, curing at least for 28 days with supply of GI wires, remove the shuttering of ferrocement L-panel, lifting the panel to floor/roof level, keeping on proper position, the cost of water, electricity and other charges all complete as per design, drawing and accepted by the Engineer-in-charge. | |||||
| 1240. | 23.4.1 | For ground floor, span up to 3810 mm for floor/roof slab. | sqm | 1612 | 1609 | 1576 | 1572 |