DIVISION 23 : FERROCEMENT WORKS
1241. 23.4.2 Add for each additional floor above ground floor sqm 40 40 40 40
1242. 23.5 Supplying, making and fitting fixing of ferrocement door/window frame 155 mm x 65 mm which is made by using M.S. rod (fy = 400 MPa) fabrication work minimum cement content relates to mix ratio 1:2 cement conforming to BDS EN-197-1-CEM-I, 52.5N (52.5MPa)/ ASTM-C 150 type–1, coarse sand (F.M. 2.2), cutting, bending, binding of one layer 20 BWG galvanized / epoxy coated wire mesh having minimum yield strength fy=450 MPa & 12 mm c/c gap in both directions with 24 BWG. G.I. wire, jute hassain, polythene sheet, placing of 100 mm long welded iron hinges including 6 mm dia M.S. rod clamp fittings, fixing in position, casting with neat cement finishing demoulding and lean cement sand (1:8) cement, sand (F.M. 1:2) and curing at least for 28 days etc. all complete including the cost of water, electricity, testing and other charge as per design, drawing and accepted by the Engineer-in-charge. (Considering x- section of the frame is 153 mm x 64 mm). meter 707 703 680 679
1243. 23.6 25mm thick cast-in-situ ferrocement wall with minimum cement content relates to mix ratio 1:2, cement conforming to BDS EN-197-1-CEM-I, 52.5N (52.5MPa)/ASTM-C 150 type–1, and best quality coarse sand (F.M. 2.2) M.S. rod fabrication in accordance with BDS, ISO 6935-2:2006 straighting and cleaning rust if any, bending and binding in position with supply of 8 mm dia M.S. rod 250 mm c/c vertically, 6 mm dia 250 mm c/c horizontally, 24 nos G.I. wire splices laps etc. 2 layers of 20 BWG galvanized wire mesh having minimum yield strength fy=450 Mpa & 2 mesh per 25 mm, casting and finishing the both surfaces with cement sand (F.M.-1.2) mortar (1:3) and curing at least for 21 days, including the cost of water, electricity and other charges in all complete as per drawing, design and accepted by the Engineer-in-charge. sqm 2066 2054 2004 2003
1244. 23.7 Supplying, fitting & fixing of 25 mm thick pre-cast ferrocement wall panel with minimum cement content relates to mix ratio 1:2, cement conforming to BDS EN-197-1-CEM-1, 52.5N (52.5MPa)/ ASTM-C 150 type–1 and best quality coarse sand (F.M. 2.2) and 2 layers of 20 BWG galvanized wire mesh having minimum yield strength fy=450 Mpa & 2 mesh per 25 mm, including cutting, binding, bending, with 24 B.W.G. G.I. wire, casting and finishing the both surfaces with cement sand (F.M.-1.2) Mortar (1:3) and curing at least for 21 days before lifting, fitting & fixing the Ferrocement plate in proper position with making rib, supply of 8 mm dia M.S. rod 250 mm c/c vertically, 6 mm dia 250 mm c/c horizontally fabrication in accordance with BDS, ISD 6935-2.2006 straighting and cleaning rust if any, bending and binding in position with supply of G.I. wire etc. the cost of water, electricity and other charges, complete in all respect and accepted by the Engineer-in-charge
1245. 23.7.1 Ground Floor sqm 1805 0 0 0
1246. 23.7.2 Add for each additional floor above ground floor sqm 20 20 20 20
1247. 23.8 90 mm thick partition wall with ferrocement sandwich panel wall (cast in situ) using mortar having compressive strength not less than 15.0 N/mm2 and fitting-fixing of EPS sheet size (3000 mm x 1200 mm x 63 mm),8 mm M.S. bar and its fabrication in both side with 20 BWG galvanized wire mesh having minimum yield strength fy=450 Mpa & 2 mesh per 25 mm, in compliance with ASTM C129 fairly uniform thickness and water absorption not more than 7% including necessary scaffolding, cleaning and curing at least for 7 days including cost of water, electricity and other charges etc. in all complete accepted by the Engineer-in-charge.
1248. 23.8.1 Ground Floor sqm 2400 2392 2345 2344
1249. 23.8.2 Add for each additional floor above ground floor sqm 15 15 15 15
1250. 23.9 40 mm ferro-cement slab on soil-cement stabilized sub-grade in ground floor etc. with minimum cement content relates to mix ratio 1:2 having minimum compressive strength of 30 MPa (28 days standard cube strength) and cement conforming to BDS EN-197-1-CEM-1, best quality coarse (F.M. 2.2) sand, 2 layer of 20 BWG galvanized/epoxy coated wire mesh having minimum yield strength fy=450 Mpa & having 2 mesh per 25 mm with minimum clear cover 12 mm both top & bottom, true to desired level, placing, compacting, curing at least for 7 days in all floors including cost of water, electricity and other charges etc. all complete and accepted by the Engineer-in-charge. sqm 1394 1391 1370 1369