| SL# | Item Code | Item Description | Unit |
Rate for ZoneA Dhaka & Mymensingh Division |
Rate for ZoneB Chattogram & Sylhet Division |
Rate for ZoneC Rajshahi & Rangpur Division |
Rate for ZoneD Khulna & Barishal Division |
|---|---|---|---|---|---|---|---|
| DIVISION 23 : FERROCEMENT WORKS | |||||||
| 1241. | 23.4.2 | Add for each additional floor above ground floor | sqm | 40 | 40 | 40 | 40 |
| 1242. | 23.5 | Supplying, making and fitting fixing of ferrocement door/window frame 155 mm x 65 mm which is made by using M.S. rod (fy = 400 MPa) fabrication work minimum cement content relates to mix ratio 1:2 cement conforming to BDS EN-197-1-CEM-I, 52.5N (52.5MPa)/ ASTM-C 150 type–1, coarse sand (F.M. 2.2), cutting, bending, binding of one layer 20 BWG galvanized / epoxy coated wire mesh having minimum yield strength fy=450 MPa & 12 mm c/c gap in both directions with 24 BWG. G.I. wire, jute hassain, polythene sheet, placing of 100 mm long welded iron hinges including 6 mm dia M.S. rod clamp fittings, fixing in position, casting with neat cement finishing demoulding and lean cement sand (1:8) cement, sand (F.M. 1:2) and curing at least for 28 days etc. all complete including the cost of water, electricity, testing and other charge as per design, drawing and accepted by the Engineer-in-charge. (Considering x- section of the frame is 153 mm x 64 mm). | meter | 707 | 703 | 680 | 679 |
| 1243. | 23.6 | 25mm thick cast-in-situ ferrocement wall with minimum cement content relates to mix ratio 1:2, cement conforming to BDS EN-197-1-CEM-I, 52.5N (52.5MPa)/ASTM-C 150 type–1, and best quality coarse sand (F.M. 2.2) M.S. rod fabrication in accordance with BDS, ISO 6935-2:2006 straighting and cleaning rust if any, bending and binding in position with supply of 8 mm dia M.S. rod 250 mm c/c vertically, 6 mm dia 250 mm c/c horizontally, 24 nos G.I. wire splices laps etc. 2 layers of 20 BWG galvanized wire mesh having minimum yield strength fy=450 Mpa & 2 mesh per 25 mm, casting and finishing the both surfaces with cement sand (F.M.-1.2) mortar (1:3) and curing at least for 21 days, including the cost of water, electricity and other charges in all complete as per drawing, design and accepted by the Engineer-in-charge. | sqm | 2066 | 2054 | 2004 | 2003 |
| 1244. | 23.7 | Supplying, fitting & fixing of 25 mm thick pre-cast ferrocement wall panel with minimum cement content relates to mix ratio 1:2, cement conforming to BDS EN-197-1-CEM-1, 52.5N (52.5MPa)/ ASTM-C 150 type–1 and best quality coarse sand (F.M. 2.2) and 2 layers of 20 BWG galvanized wire mesh having minimum yield strength fy=450 Mpa & 2 mesh per 25 mm, including cutting, binding, bending, with 24 B.W.G. G.I. wire, casting and finishing the both surfaces with cement sand (F.M.-1.2) Mortar (1:3) and curing at least for 21 days before lifting, fitting & fixing the Ferrocement plate in proper position with making rib, supply of 8 mm dia M.S. rod 250 mm c/c vertically, 6 mm dia 250 mm c/c horizontally fabrication in accordance with BDS, ISD 6935-2.2006 straighting and cleaning rust if any, bending and binding in position with supply of G.I. wire etc. the cost of water, electricity and other charges, complete in all respect and accepted by the Engineer-in-charge | |||||
| 1245. | 23.7.1 | Ground Floor | sqm | 1805 | 0 | 0 | 0 |
| 1246. | 23.7.2 | Add for each additional floor above ground floor | sqm | 20 | 20 | 20 | 20 |
| 1247. | 23.8 | 90 mm thick partition wall with ferrocement sandwich panel wall (cast in situ) using mortar having compressive strength not less than 15.0 N/mm2 and fitting-fixing of EPS sheet size (3000 mm x 1200 mm x 63 mm),8 mm M.S. bar and its fabrication in both side with 20 BWG galvanized wire mesh having minimum yield strength fy=450 Mpa & 2 mesh per 25 mm, in compliance with ASTM C129 fairly uniform thickness and water absorption not more than 7% including necessary scaffolding, cleaning and curing at least for 7 days including cost of water, electricity and other charges etc. in all complete accepted by the Engineer-in-charge. | |||||
| 1248. | 23.8.1 | Ground Floor | sqm | 2400 | 2392 | 2345 | 2344 |
| 1249. | 23.8.2 | Add for each additional floor above ground floor | sqm | 15 | 15 | 15 | 15 |
| 1250. | 23.9 | 40 mm ferro-cement slab on soil-cement stabilized sub-grade in ground floor etc. with minimum cement content relates to mix ratio 1:2 having minimum compressive strength of 30 MPa (28 days standard cube strength) and cement conforming to BDS EN-197-1-CEM-1, best quality coarse (F.M. 2.2) sand, 2 layer of 20 BWG galvanized/epoxy coated wire mesh having minimum yield strength fy=450 Mpa & having 2 mesh per 25 mm with minimum clear cover 12 mm both top & bottom, true to desired level, placing, compacting, curing at least for 7 days in all floors including cost of water, electricity and other charges etc. all complete and accepted by the Engineer-in-charge. | sqm | 1394 | 1391 | 1370 | 1369 |