| SL# | Item Code | Item Description | Unit |
Rate for ZoneA Dhaka & Mymensingh Division |
Rate for ZoneB Chattogram & Sylhet Division |
Rate for ZoneC Rajshahi & Rangpur Division |
Rate for ZoneD Khulna & Barishal Division |
|---|---|---|---|---|---|---|---|
| DIVISION 07 : REINFORCED CEMENT CONCRETE (RCC) WORKS | |||||||
| 371. | 07.19.3 | Floor and roof slab up to ground floor | sqm | 24 | 24 | 24 | 24 |
| 372. | 07.2 | Reinforced cement concrete works with minimum cement content relates to mix ratio 1:2:4 having minimum f'cr = 30.5 MPa, satisfying a specified compressive strength f'c = 22 MPa at 28 days on standard cylinders as per standard practice of Code ACI/BNBC/ASTM, cement conforming to BDS EN-197-1-CEM-I, 52.5N (52.5 MPa) / ASTM-C 150 Type – I, best quality Sylhet sand or coarse sand of equivalent F.M. 2.2 and 20 mm down well graded stone chips conforming to ASTM C-33 (Aggregate grading as per table shown in technical specification), conducting necessary tests, making and placing shutter in position maintaining true to plumb, making shutter water-tight properly, placing reinforcement in position; mixing in standard mixer machine with hopper fed by standard measuring boxes, casting in forms, compacting by vibrator machine and curing at least for 28 days, removing centering-shuttering after specified time approved; including cost of water, electricity,other charges etc. all complete, approved and accepted by the Engineer-in-charge. (Rate is excluding laboratory test fees, the cost of reinforcement and its fabrication, placing, binding etc. and the cost of shuttering & centering) | |||||
| 373. | 07.2.1 | Individual & combined footing, pile cap, raft/mat, floor slab and foundation beam up to plinth level | cum | 13508 | 13728 | 12732 | 12347 |
| 374. | 07.2.2 | Pedestals, column, column capital, lift wall and RCC wall up to ground floor | cum | 13869 | 14084 | 13067 | 12682 |
| 375. | 07.2.3 | Floor / roof slab, T-beam, L-beam and rectangular beam, tie beam, lintel, stair case slab and steps etc. up to ground floor | cum | 13652 | 13871 | 12866 | 12481 |
| 376. | 07.2.4 | Cornice, railing, drop wall, louver, fins, sunshade, false ceiling, waffle and ribbed floor slab etc. up to ground floor | cum | 14230 | 14440 | 13403 | 13018 |
| 377. | 07.20 | Added Rate of formwork in case of floor slab casting in every 10 days (applicable for buildings with number of floor Fifteen and above) *** {with prior approval from competent authority} | |||||
| 378. | 07.20.1 | Pedestal, column, column capital, lift wall and wall up to Ground floor (shutter releasing agent shall be used) | sqm | 48 | 48 | 48 | 48 |
| 379. | 07.20.2 | T-beam, L-beam and rectangular beam etc up to ground floor (shutter releasing agent shall be used) | sqm | 66 | 66 | 66 | 66 |
| 380. | 07.20.3 | Floor and roof slab up to ground floor | sqm | 62 | 62 | 62 | 62 |