Long Schedule By Division

SL# Item Code Item Description Unit Rate for ZoneA Rate for ZoneB Rate for ZoneC Rate for ZoneD
DIVISION 28 : GAS CONNECTION WORKS
1. Part - B (Domestic & Commercial line)
2. 28.1 Pipe line installation: Installation of 50 psi, APl, 5L, Grade-B, ERW Natural pipe line for supplying Titas Gas including, supplying, fitting, fixing and laying different sizes M.S. pipes with necessary tape and primer including cutting trenches (450 mm x 910 mm) in all kinds of soil, cleaning, cutting, applying coal-tar, wrapping the pipes, marking the pipeline with 200mm X 200mm demarcation plate (C.C./ M.S. plate) @ 15m interval and back filling the trenches, excavating earth including. leveling, dressing and removing excess earth in all respect as per specification of Titas Gas T and D Co. Ltd. and accepted by the Engineer-in-charge. [Rate is excluding the cost of welding and back filling with sand at the bottom by 300 mm in thickness (compacted)] (Pipes manufactured by National Tubes Limited under Steel & Engineeing Corporation, Ministry of Industries, Government of Bangladesh shall be given priority)
3. 28.1.1 100 mm ND (114.30 mm O.D) M.S pipe, weight of min 14.4 kg/m, standard test pressure 176 kg/ m2, wall thickness of min 5.4 mm Show Breakup meter 4179 4003 3983 3983
4. 28.1.2 75 mm N.D (88.90 mm O.D) M.S pipe, weight of min 10.1 kg/m, standard test pressure 176 kg/ m2, wall thickness of min 4.85 mm Show Breakup meter 2386 2283 2266 2266
5. 28.1.3 50 mm N.D. (60.30 mm O.D) M.S pipe, weight of min 6.17 kg/m, standard test pressure 176 kg/ m2, wall thickness of min 4.47 mm Show Breakup meter 1447 1383 1365 1365
6. 28.1.4 25 mm N.D. (33.80 mm O.D) M.S pipe weight of min 3.84 kg/m, standard test pressure 50 kg/ m2, wall thickness of min 4.05 mm Show Breakup meter 870 829 811 811
7. 28.1.5 20 mm N.D. (27.20 mm O.D) M.S pipe weight of min 1.90 kg/m, standard test pressure 50 kg/ m2, wall thickness of min 3.25 mm Show Breakup meter 683 649 632 632
8. 28.10 Cutting of permanent pucca (rigid/flexible) road and mending good the damages etc. all complete in all respect and accepted by the Engineer-in-charge.
9. 28.10.1 Bituminous Road Show Breakup sqm 1356 1277 1182 1182
10. 28.10.2 R.C.C. Road Show Breakup sqm 2027 1910 1769 1769
11. 28.11 Testing and purging of the house line properly as per specifications Titas Gas T and D Co. Ltd. and accepted by the Engineer-in-charge. Show Breakup meter 29 28 28 28
12. 28.12 Supplying and installation the complete LP Gas Reticulated System for highrise buildings (Upto 40 unit 20 storied) with Storage facility (45 KG POL Valve cylinders/Bulk Tank) with isolation and safety valve, pressure gauges, LPG transfer hose, Seamless MS pipe network, LPG Regulator (1st Stage and 2nd Stage), Household LP Gas meter, Safety fittings & accessories, system design, documentation, supervision and commissioning etc. (as per standard of department of Explosive and NFPA-58) all complete and accepted by engineer in charge.
13. 28.12.1 Cylinder heading line for multistoried Building with 40 unit apartment, 2X10 Nos cylinder Heading line, 45 Kg LP Gas Cylinder Bank Vapor Off Take (VOT) System with MS Seamless SCH 40 pipes. (min. dia 25 mm), Flanze Type MS 150 class ball valve, Pressure Gauge (100 mm dia) liquid type (range: 0-20 Bar), Bleed Valve, Safety Relief Valve (LPG Type, Relief at 14.6 Bar)), LP Gas pigtal, Ball valve and necessary fittings suitable for LP Gas as per standard of department of Explosive and NFPA-58), Supply, Installation of Medium pressure main distribution pipeline, MS Seamless (Sch-40) 50 mm dia pipe upto 100 meter length, Flanze Type MS Valve 150 Class Dia 50 mm, Sch 40 MS 50 mm TEE , Sch 40 MS 50 mm Elbow, 150 Class 50 mm MS Flanze , Painting, Pipe support with MS Clamp, First Stage Regulator ; Brand: REGO / FISHER / CAVAGNA or similar from USA or EU, MS Seamless SCH 40 pipes, Flanze Type MS 150 class ball valve, Pressure Gauge (100 mm dia) liquid type (range: 0-20 Bar), Bleed Valve, Safety Relief Valve (LPG Type, Relief at 14.6 Bar) etc. as per requirement all complete, approved and accepted by the Engineer-in-charge. (All the welding joints must be TIG welded)(Rate is excluding the cost of shed, perimeter fencing and RCC floor). Show Breakup set 1159540 1159540 1159540 1159540
14. 28.12.2 Reduction cost per unit below 40 unit connection for all necessary arrangement including heading line. Show Breakup each 10000 10000 10000 10000
15. 28.12.3 Additional cost per apartment upto 100 apartment for all necessary arrangement including heading line. Show Breakup each 9203 9203 9203 9203
16. 28.12.4 Supplying and installation of 45 Kg LP Gas empty cylinder cylinder [Water capacity: 108 litre; design code: DOT, Service pressure 17 Kgs/cm2, test pressure 34 Kgs/cm2, Steel grade SG295 or equiv.], certified by Department of Explosives. Show Breakup each 7362 7362 7362 7362
17. 28.13 Supplying and instalation of LP Gas Prepaid meter with smart recharging system. (Smart card for recharge gas, Meter connection, Second Stage Regulator, Gas meter header with individual valves (MS 150 class) in both ends of meter and other fittings etc. all complete and accepted by the Engineer-in-charge. Show Breakup each 24541 24541 24541 24541
18. 28.2 Providing Butt welded joints with pipes to Tees, Elbows, Saddles, end caps etc above or below ground including. cutting and V-leveling in each end of the pipe, grinding by machine etc. complete as per specification of Titas Gas T and D C Ltd. and accepted by the Engineer-in-charge.
19. 28.2.1 75 mm N.D (88.90 mm O.D)-6.95 mm Show Breakup each 280 269 269 269
20. 28.2.2 50 mm N.D (60.30 mm O.D)-5.15 mm Show Breakup each 240 231 231 231
21. 28.2.3 25.mm N.D (33.40 mm O.D)-4.2mm Show Breakup each 187 179 179 179
22. 28.2.4 20 mm N.D (26.70 mm O.D)-3.35mm Show Breakup each 160 154 154 154
23. 28.3 Supplying, fitting and fixing the following materials including carriage to the work site from Titas Gas Store as per specification of Titas Gas (T and D) Co. Ltd. and accepted by the Engineer-in-charge. (Rate is excluding the cost of welding)
24. 28.3.1 50 mm x 50 mm x 50 mm (N.D) equal tee Show Breakup each 315 302 301 301
25. 28.3.10 50 mm dia end cap Show Breakup each 104 100 99 99
26. 28.3.11 25 mm dia end cap Show Breakup each 113 109 108 108
27. 28.3.2 50 mm x 50 mm x 25 mm (N.D) reducing tee Show Breakup each 513 492 491 491
28. 28.3.3 25 mm x 25 mm x 25 mm (N.D) equal tee Show Breakup each 182 174 173 173
29. 28.3.4 50 mm x 90º elbow Show Breakup each 255 244 243 243
30. 28.3.5 25 mm x 90º elbow Show Breakup each 215 206 205 205
31. 28.3.6 50 mm x 25 mm 45º elbow Show Breakup each 117 112 111 111
32. 28.3.7 50 mm x 25 mm reducer. Show Breakup each 135 129 128 128
33. 28.3.8 20 mm plug, socket Show Breakup each 529 507 506 506
34. 28.3.9 50mm X 20 mm saddle Show Breakup each 435 417 416 416
35. 28.4 Supplying, welding, fitting and fixing of different size valve tee/ service tee to connect the pipe line with the Titas Gas Main pipe line etc. all complete in all respect as per specification of Titas Gas T and D Co. Ltd. approved and accepted by the Engineer-in-charge.
36. 28.4.1 50 mm x 50 mm Valve Tee (50 mm and above 50 mm low pressure line) Sch 40 Show Breakup each 16799 16060 15821 15821
37. 28.4.2 50 mm x 25 mm Valve Tee Show Breakup each 3071 2902 2722 2722
38. 28.4.3 25 mm x 25 mm Service Tee Show Breakup each 6976 6655 6501 6501
39. 28.4.4 50 mm x 25 mm Service Tee Show Breakup each 13618 13016 12811 12811
40. 28.5 Supplying, fitting and fixing in position different dia I/F (Insulated Flange) etc. all complete in all respect as per specification of Titas Gas T and D Co. Ltd. approved and accepted by the Engineer-in-charge. 50 mm N.D. (60.30 mm O.D) Insulation Flange. Show Breakup each 7190 6841 6610 6610
41. 28.6 Construction of 1520 mm x 1520 mm x 1370 mm (depth) water-tight valve pit, enclosed by 250 mm thick brick wall in 1:6, plastered on each face in 1:4 with net cement finishing, having a 75 mm thick C.C (1:3:6) bed upon a layer of brick flat soling, over laid by 38 mm thick patent stone flooring including standard M.S. sheet valve pit cover as per drawing and specification of Titas Gas T and D Co. Ltd. etc. all complete in all respect and accepted by the Engineer-in-charge. Show Breakup each 122533 122199 120365 120183
42. 28.7 Supplying, fitting and fixing of ball valve class 150 RF including supplying of 2 Nos. flange along with necessary nuts and bolts, welding the flange etc. all complete in all respect as per specification of Titas Gas T and D Co. Ltd. approved and accepted by the Engineer-in-charge.
43. 28.7.1 50 mm ball valve class 150 RF. 2" dia Show Breakup each 18713 17862 17491 17491
44. 28.7.2 25 mm ball valve class 150 RF.1" dia Show Breakup each 14479 13800 13428 13428
45. 28.8 Riser Pipe line installation: Installation of 2 psi, APl, 5L, Grade-B, ERW Natural pipe line for supplying Titas Gas including, supplying, fitting, fixing and laying different sizes M.S. pipes with necessary tape and painting in all respect as per specification of Titas Gas T and D Co. Ltd. and accepted by the Engineer-in-charge. [Rate is excluding the cost of welding and tee, elbow socket etc fittings ] (Pipes manufactured by National Tubes Limited under Steel & Engineeing Corporation, Ministry of Industries, Government of Bangladesh shall be given priority)
46. 28.8.1 12 mm N.D. with wall thickness 2 mm Show Breakup each 319 318 312 312
47. 28.8.2 20 mm N.D.with wall thickness 2.35 mm Show Breakup each 387 385 379 379
48. 28.9 Supplying, fitting and fixing in position different dia one-way brass stop cock (best quality and heavy type) etc. complete in all respect as per specification of Titas Gas T and D Co. Ltd. approved and accepted by the Engineer-in-charge.
49. 28.9.1 12 mm x 6 mm N.D. Show Breakup each 404 387 384 384
50. 28.9.2 20 mm x 20 mm N.D. Show Breakup each 729 698 694 694
Help